SearchFAQMemberlist Log in
Reply to topic Page 1 of 1
Error Unable to position to end of data on device Drive-1
Author Message
Post Error Unable to position to end of data on device Drive-1 
Hello,

my problem is describe in the object. When i run the backup the backup go on and end fine. But a new backup on the same tape mark it error and take another tape.


This is the error on bacula log :


12-Dec 10:40 bak02prdost.recupitalia.it-sd JobId 35: Volume "000101L" previously written, moving to end of data.
12-Dec 10:41 bak02prdost.recupitalia.it-sd JobId 35: Error: Unable to position to end of data on device "Drive-1" (/dev/nst1): ERR=dev.c:966 ioctl MTIOCGET error on "Drive-1" (/dev/nst1). ER R=Success.
12-Dec 10:41 bak02prdost.recupitalia.it-sd JobId 35: Marking Volume "000101L" in Error in Catalog.
12-Dec 10:42 bak02prdost.recupitalia.it-sd JobId 35: Please mount Volume "000103L" or label a new one for:




This is my connfiguration on server:


O.S : CentOS release 5.6
Kernel : 2.6.18-238.12.1.el5 x64
Bacula Version : 5.0.3 (from rpm).
Library : Spectralogic T50e with LTO-4 Drive FC


I try to run a btape test with good result , this is the output :


=== Forward space files test ===


This test is essential to Bacula.


I'm going to write five files then test forward spacing


btape: btape.c:578 Rewound "Drive-1" (/dev/nst1)
btape: btape.c:1905 Wrote one record of 64412 bytes.
btape: btape.c:1907 Wrote block to device.
btape: btape.c:608 Wrote 1 EOF to "Drive-1" (/dev/nst1)
btape: btape.c:1905 Wrote one record of 64412 bytes.
btape: btape.c:1907 Wrote block to device.
btape: btape.c:1905 Wrote one record of 64412 bytes.
btape: btape.c:1907 Wrote block to device.
btape: btape.c:608 Wrote 1 EOF to "Drive-1" (/dev/nst1)
btape: btape.c:1905 Wrote one record of 64412 bytes.
btape: btape.c:1907 Wrote block to device.
btape: btape.c:1905 Wrote one record of 64412 bytes.
btape: btape.c:1907 Wrote block to device.
btape: btape.c:1905 Wrote one record of 64412 bytes.
btape: btape.c:1907 Wrote block to device.
btape: btape.c:608 Wrote 1 EOF to "Drive-1" (/dev/nst1)
btape: btape.c:1905 Wrote one record of 64412 bytes.
btape: btape.c:1907 Wrote block to device.
btape: btape.c:1905 Wrote one record of 64412 bytes.
btape: btape.c:1907 Wrote block to device.
btape: btape.c:608 Wrote 1 EOF to "Drive-1" (/dev/nst1)
btape: btape.c:1905 Wrote one record of 64412 bytes.
btape: btape.c:1907 Wrote block to device.
btape: btape.c:608 Wrote 1 EOF to "Drive-1" (/dev/nst1)
btape: btape.c:608 Wrote 1 EOF to "Drive-1" (/dev/nst1)
btape: btape.c:578 Rewound "Drive-1" (/dev/nst1)
btape: btape.c:1632 Now forward spacing 1 file.
We should be in file 1. I am at file 1. This is correct!
btape: btape.c:1644 Now forward spacing 2 files.
We should be in file 3. I am at file 3. This is correct!
btape: btape.c:578 Rewound "Drive-1" (/dev/nst1)
btape: btape.c:1657 Now forward spacing 4 files.
We should be in file 4. I am at file 4. This is correct!


btape: btape.c:1675 Now forward spacing 1 more file.
We should be in file 5. I am at file 5. This is correct!


=== End Forward space files test ===





The bacula-sd if configured with :


Autochanger {
Name = spectra
Device = Drive-1
Changer Command = "/usr/lib64/bacula/mtx-changer %c %o %S %a %d"
Changer Device = /dev/sg2
}


Device {
Name = Drive-1 #
Drive Index = 1
Media Type = LTO-4
Archive Device = /dev/nst1
Changer Device = /dev/sg2
TWO EOF = yes
AlwaysOpen = yes;
AutomaticMount = yes; # when device opened, read it
RemovableMedia = yes;
RandomAccess = no;
Maximum File Size = 5GB
SpoolDirectory = /opt/stage/SpoolDirectory
Maximum Spool Size = 25GB # 25 Gb of spool
Alert Command = "sh -c 'tapeinfo -f %c |grep TapeAlert|cat'"
}





I try to use the this on bacula-sd configuration


# Hardware End of Medium = no


But with this option i can't run the backup.


The IBM-Drive is on the lastest firmware upgrade (B711).


p.s: I have another server (the same configuration on another library T200) and work fine with lto4.


Anyone can help me? Thank you.








--
Daniele Eccher
Gruppo Darco - ICT Sistemi
Via Ostiense 131/L Corpo B, 00154 Roma
E-mail: daniele.eccher < at > sociale.it ([email]daniele.eccher < at > sociale.it[/email]) tel : +39 06 57060 500 cell : +39 346 1426128